Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 450: 139260, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38626714

RESUMO

High fluorescence intensity microspheres such as aggregation-induced emission fluorescence microspheres (AIEFM) have improved the sensitivity of lateral flow immunoassay (LFIA). The preparation of immune probes in LFIA usually adopts the chemical coupling strategy with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide for antibody coupling, which has the problems of low coupling efficiency, tedious coupling process, and poor repeatability. A biocompatible metal-phenolic network (MPN), which contains large amounts of phenols and galloyl groups, could easily, quickly, and stably couple with antibodies. Herein, we proposed a strategy based on MPN modification on ultrabright AIEFM surface as a novel label for the rapid detection of carbendazim. The limit of detection of AIEFM@MPN-LFIA was 0.019 ng/mL, which was 4.9 times lower than that of AIEFM-LFIA. In spiked samples, the average recoveries of AIEFM@MPN-LFIA ranged from 80% to 118% (coefficient of variation <13.45%). Therefore, AIEFM@MPN was a promising signal label that could improve the detection performance of LFIA.

2.
Food Chem ; 450: 139380, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38640535

RESUMO

Pyrimethanil (PYR) is a fungicide that is harmful to consumers when present in foods at concentrations greater than maximum permitted residue levels. High-performance immunoprobes and dual-readout strategy may be useful for constructing sensitive lateral flow immunoassay (LFIA). Herein, the prepared litchi-like Au-Ag bimetallic nanospheres (LBNPs) exhibited high mass extinction coefficients and fluorescence quenching constants. Benefiting from LBNPs and dual-readout mode, the limits of detection of LBNPs-CM-LFIA and LBNPs-FQ-LFIA for PYR were 0.957 and 0.713 ng mL-1, which were 2.54- and 3.41-fold lower than that of gold nanoparticles-based LFIA, respectively. The limits of quantitation of LBNPs-CM-LFIA and LBNPs-FQ-LFIA were 3.740 and 1.672 ng mL-1, respectively. LBNPs-LFIA was applied to detect PYR in cucumber and grape samples with satisfactory recovery (90%-111%). LBNPs-LFIA showed good agreement with LC-MS/MS for the detection of PYR in the samples. Accordingly, this sensitive and accurate dual-readout LFIA based on LBNPs can be effectively applied for food safety.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...